Mesa Home>Nusonics>Flow Meters>CM-800 HVAC / Municipal / Industrial Flow Meter>Specifications

CM-800 Specifications

Measurement Capabilities

Range 0.3 to 50 ft/sec
Pipe Diameter 2"-200" (50 mm to 5080 mm)
Accuracy

+/- 1/2 to 1% of flow reading above 1ft/sec (0.3m/sec)
+/- 1 to 2% of flow reading 0.3 to 1 ft/sec (0.9 to 0.3m/sec)

Repeatability 0.2%
Linearity 0.1%
Turndown 167:1

Operating Specs-Transducers

Liquid Temperature -40 F to 302 F (-40 C to 150 C)
Liquid Pressure

CPVC: 250 psig @ 27C
Metal: 1000 psig @150 C
Metal: 3500 psig optional

Sensors NEMA 7 connection heads standard
Optional Permanently submersible
Sensor Materials 1" & 2" CPVC; 1/2", 1", 2" titanium, others materials available
Cable Length (Max) 1000 ft. (310 m)

Transmitter

Analog isolated current output 4-20 mA forward and reverse into 1000 ohm load max. Fault relay, SPST, 130 volt, 0.5A resistive max. 0-5 volt pulse output.  RS232 standard/RS485 optional

Environment & Power

Enclosures

NEMA 4X standard, 10 lb. Optional: NEMA 7 explosion proof, class 1, groups C&D

Power

115 or 230 VAC +/- 10%, 50-60 Hz 24VDC optional

Consumption

12 watts

Humidity

0-100%, non-condensing

Hand-Held Configurator

30 position keypad, 4 x 20 LCD display powered by the transmitter, supplied with 7' coil cable and connector.

Computer Mode

All functions for setup and measurement available through RS232/RS485 interface.

Optional Remote Displays ALP-R & ALP-RT

Rate only

3 1/2 digit LCD, 0.5" character height with user selectable trailing zero rate. -1999 to 1999 span (-19990 to 19990 with trailing zero enabled)

Decimal Point

Adjustable

Rate and Total

8-digit LCD, 0.5" character height

Time Base

Selectable, battery backup of total, typical 8 month data retention

Reset

Push button or remote contact.  Optional alarms high/low, opto-isolated, open collector 30 VDC max.

Related Items

CM-800 Brochure

Service

Sales Reps

Additional Information

(click to inlarge)
CM-800 Flow Meter
Flow Tube