CM-800 Specifications
Measurement Capabilities
| Range | 0.3 to 50 ft/sec |
| Pipe Diameter | 2"-200" (50 mm to 5080 mm) |
| Accuracy | +/- 1/2 to 1% of flow reading above 1ft/sec (0.3m/sec) |
| Repeatability | 0.2% |
| Linearity | 0.1% |
| Turndown | 167:1 |
Operating Specs-Transducers
| Liquid Temperature | -40 F to 302 F (-40 C to 150 C) |
| Liquid Pressure | CPVC: 250 psig @ 27C |
| Sensors | NEMA 7 connection heads standard |
| Optional | Permanently submersible |
| Sensor Materials | 1" & 2" CPVC; 1/2", 1", 2" titanium, others materials available |
| Cable Length (Max) | 1000 ft. (310 m) |
Transmitter
Analog isolated current output 4-20 mA forward and reverse into 1000 ohm load max. Fault relay, SPST, 130 volt, 0.5A resistive max. 0-5 volt pulse output. RS232 standard/RS485 optional
Environment & Power
| Enclosures | NEMA 4X standard, 10 lb. Optional: NEMA 7 explosion proof, class 1, groups C&D |
| Power | 115 or 230 VAC +/- 10%, 50-60 Hz 24VDC optional |
| Consumption | 12 watts |
| Humidity | 0-100%, non-condensing |
Hand-Held Configurator
30 position keypad, 4 x 20 LCD display powered by the transmitter, supplied with 7' coil cable and connector.
Computer Mode
All functions for setup and measurement available through RS232/RS485 interface.
Optional Remote Displays ALP-R & ALP-RT
| Rate only | 3 1/2 digit LCD, 0.5" character height with user selectable trailing zero rate. -1999 to 1999 span (-19990 to 19990 with trailing zero enabled) |
| Decimal Point | Adjustable |
| Rate and Total | 8-digit LCD, 0.5" character height |
| Time Base | Selectable, battery backup of total, typical 8 month data retention |
| Reset | Push button or remote contact. Optional alarms high/low, opto-isolated, open collector 30 VDC max. |